Sign In | Join Free | My benadorassociates.com
China SKYLINE INSTRUMENTS CO.,LTD logo
SKYLINE INSTRUMENTS CO.,LTD
SKYLINE INSTRUMENTS CO.,LTD
Verified Supplier

1 Years

Home > Fire Testing Equipment >

IEC60695-11-03 Fire Testing Equipment Single Cable Vertical Flammability Tester

SKYLINE INSTRUMENTS CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

IEC60695-11-03 Fire Testing Equipment Single Cable Vertical Flammability Tester

Brand Name : SKYLINE

Model Number : SL-7603C

Certification : CE

Place of Origin : China

MOQ : 1 unit

Price : negotiated

Payment Terms : T/T, L/C, Western Union, MoneyGram

Supply Ability : 1 unit/ month

Delivery Time : 10 working days

Packaging Details : Plywood case

Standards : IEC60332-1-1:2004

Vertical burning chamber : W300xH1200xD450mm

Length of specimen : 600±25mm

Gas flow range : 0.1-1L/min

Contact Now

IEC60695-11-03 Single Cable Vertical Flammability Tester

Product introduction

Single Cable Combustion Tester is the most widely used and lower cost of cable fire performance test equipment, which can meet the standards IEC 60332-1-1:2004 in the provisions of technical indicators and requirements. Single cable combustion Tester is used to test the flame retardant property of the cable's insulating layer under abnormal conditions such as overheat and overcurrent. It can be used in vertical cable or fiber flame spread test, also can be test the state of flaming droplets during combustion.

Application
Applies to check thesingle insulation wire and cable vertical spreading test which total section area less than 0.5mm2
Standards
According to IEC60332-1-1:2004, IEC60332-1-2:2004, IEC60332-1-3:2004, EN50265-1, EN50265-2-1
Main parameters
Vertical burning chamber W300xH1200xD450mm
Gas Use high purity propane gas or liquefied petroleum gas (provide by user-self)
Specimen length 600±25mm
Area of specimen Total section area less than 0.5mm2
Testing temperature This device is located in a stuffiness room and the temperature keeping the 23±10℃ for testing
Burning time continuously setting between 0.1-999.9S, during the setting time flame could continuously burning the specimen
Control function Switch can choose to be manual or automatically according to the actual needed
Gas flow range 0.1-1L/min
Area flow range 0.1-1m3/h
Burner 500W for standards power, 125±25mm for total height of the flame
Temperature measurement system according to GB/T5169.14-2007 and IEC60695-11-03 standard requirements, including temperature copper (10g), K type thermocouple and diameter is 0.5 mm with stainless steel sheathed, stopwatch and thermometer etc.

Automotive Single Wire.pdf

IEC60695-11-03 Fire Testing Equipment Single Cable Vertical Flammability Tester
What is a Vertical flame Test?
A test specimen is positioned vertically above a controlled flame and exposed for a specified period of time. Following exposure, the flame source is removed. Measurements are made on the length of time that the specimen continues to flame and the time afterglow continues after the flame source has been removed.
What is the flame exposure test for a cable?
Table 1: UL Control and Instrumentation Cable Standards Containing Vertical Flame Tests The UL Flame Exposure test of UL 1685 measures the flame spread in groups of cables in a steel ladder tray. The tray is 12 inches wide, 3 inches deep and 96 inches long.

Product Tags:

flammability test apparatus

      

flammability testing labs

      
Quality IEC60695-11-03 Fire Testing Equipment Single Cable Vertical Flammability Tester for sale

IEC60695-11-03 Fire Testing Equipment Single Cable Vertical Flammability Tester Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SKYLINE INSTRUMENTS CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)